Engineering & Model Selection

Vertical Turbine Pump Models

Use this ACCA engineering hub to narrow vertical turbine pump configurations by bowl size, hydraulic duty, impeller type, stage count, materials and application—then confirm the final selection from the required flow, total dynamic head, submergence, setting and driver.

Start With the Hydraulic Duty

A model designation is only the beginning of a vertical turbine selection. The bowl assembly must operate at the required capacity and head while satisfying NPSH, minimum submergence, bowl pressure, shaft loading, driver horsepower and site geometry. For replacement work, ACCA can start from an existing model or bowl designation and engineer the replacement around the actual duty.

Flow

Required GPM establishes the practical hydraulic family and bowl diameter. Larger bowls generally cover higher capacities, while the final operating point must remain within the selected performance curve.

Total Dynamic Head

TDH establishes the pressure the pump must develop. With turbine bowls, additional stages can add head while the basic flow range of the selected hydraulic remains essentially unchanged.

Submergence & NPSH

Minimum water level, drawdown and suction-bell elevation must provide adequate submergence and NPSH margin and avoid vortexing or air entrainment.

Setting & Driver

Column length, lineshaft, thrust, speed, horsepower, motor or gear drive and discharge-head arrangement are engineered as part of the complete pump—not selected independently.

Bowl Size & Hydraulic Range

Vertical turbine bowl diameter is a useful first screening dimension, but it is not a capacity rating by itself. Hydraulic design, speed and impeller trim determine the actual curve. ACCA selections can cover compact deep-well bowls through large wet-pit and high-capacity configurations; the main ACCA VTP range extends to approximately 15,500 GPM and 1,730 ft of head, subject to the selected hydraulic and number of stages.

Small & Medium Bowls

Common in water wells, municipal supply, irrigation and industrial-water systems where casing diameter and setting constrain the pump envelope.

Large Turbine Bowls

Used as capacity increases for municipal intake, industrial water, cooling water, irrigation and other high-flow services.

Mixed-Flow Bowls

Useful where the application calls for higher flow at moderate head. Hydraulic selection balances capacity, head per stage, efficiency and required submergence.

Axial / Propeller Hydraulics

Applied to very-high-flow, low-head duties such as drainage, flood control and large water-transfer systems where a conventional radial turbine hydraulic is not the best fit.

See the complete ACCA Vertical Turbine Pumps capability overview →

Impeller Types

Enclosed Impeller

A common vertical turbine configuration for clean-water and general industrial service. The impeller operates within diffuser bowls and is selected from the performance curve for the required duty.

Semi-Open Impeller

Available on selected hydraulics where the application benefits from a more open passage or where solids and wear considerations differ from conventional enclosed-impeller service.

Mixed-Flow Impeller

Develops head through both radial and axial velocity components, providing an effective solution for higher-capacity, moderate-head applications.

Axial-Flow Propeller

Moves liquid primarily parallel to the shaft and is suited to exceptionally high capacity at comparatively low head.

Single-Stage & Multistage Selection

One impeller and diffuser bowl form one hydraulic stage. For a selected turbine hydraulic, adding stages increases total developed head while the operating flow remains tied to the bowl’s performance range. Stage count is therefore determined from the required TDH and practical head per stage at the selected duty point—not simply from pump depth.

Single Stage

Appropriate when one bowl stage can produce the required head at the desired capacity and speed.

Multiple Stages

Stages are added in series for higher-head service. Final design must also verify bowl pressure, shaft power, thrust, shaft stretch and driver capacity.

Impeller Trim & Speed

Impeller diameter and operating speed provide additional selection flexibility. Final trim should be based on the manufacturer’s hydraulic curve rather than a nominal model size alone.

Materials of Construction

ACCA can configure the bowl assembly, impellers, shafts and related wetted components around the liquid and project specification. Material selection should account for corrosion, chlorides, abrasion, potable-water requirements and expected service life.

Cast / Ductile Iron

Practical for many clean-water and general municipal or industrial applications when the water chemistry permits.

Bronze

Frequently used for impellers and wear components in water service where improved corrosion performance is desired.

316 Stainless Steel

Available for shafts, impellers and other wetted components where increased corrosion resistance is required.

Nickel-Aluminum Bronze & Special Alloys

Available for selected corrosive, marine and demanding water services when supported by the liquid chemistry and project requirements.

Application-Based Model Selection

Municipal & Deep Wells

Select from required production rate, pumping water level, drawdown, well diameter, TDH, setting and potable-water requirements.

Raw-Water Intake

Consider minimum water elevation, sump geometry, submergence, debris, corrosion and continuous-duty operating range.

Industrial & Cooling Water

Selection may be driven by high duty cycle, system pressure, material requirements, redundancy and compatibility with existing piping and controls.

Irrigation

High-capacity groundwater or surface-water service is selected around seasonal water levels, system pressure, efficiency and available driver power.

Mining & Dewatering

Water chemistry, suspended solids, abrasion, changing water levels and site accessibility can materially affect hydraulic and material selection.

Flood Control & Drainage

High-flow, low-head duties may favor mixed-flow or axial-flow hydraulics rather than a conventional multistage turbine selection.

ACCA Vertical Turbine Model Cross Reference

Use the table below to identify existing equipment ACCA has referenced for replacement pump and parts inquiries. ACCA part/model references use the A- prefix. These references are an identification aid; final compatibility requires confirmation of the complete bowl assembly, impeller, stages, materials, shafting, column and operating conditions.

ACCA ModelManufacturer ReferenceModel / Bowl Reference
A-5CLC/CHCGoulds®5CLC/CHC
A-6CLC/CHCGoulds®6CLC/CHC
A-7CLC/CHCGoulds®7CLC/CHC
A-8RJLC/RJHCGoulds®8RJLC/RJHC
A-9RLC/RCHCGoulds®9RLC/RCHC
A-9BLC/9BHCGoulds®9BLC/9BHC
A-11CLC/CMC/CHCGoulds®11CLC/CMC/CHC
A-12CHCGoulds®12CHC
A-16RGLCGoulds®16RGLC
A-20EHCGoulds®20EHC
A-8YSJ-Line®8YS — Bowl 5503
A-10YCJ-Line®10YC — Bowl 3541 / Impeller 3540
A-10ZCJ-Line®10ZC — Bowl 3864 / Impeller 3862
A-12MSJ-Line®12MS — Bowl 2952 / Impeller 2951
A-14LSJ-Line®14LS — Bowl 3106 / Impeller 3105
A-14WCJ-Line®14WC — Bowl 4152
A-10MAPeerless®10MA — Impeller 2624288
A-12MBPeerless®12MB — Impeller 2624332
A-12MBPeerless®12MB — Impeller 2624331
A-14HHPeerless®14HH — 2621973
A-14HHPeerless®14HH — 2621959
A-18HHPeerless®18HH — 2621974
A-18HHPeerless®18HH — 2621975
A-24HHPeerless®24HH — 2621597
A-24HHPeerless®24HH — 2620986
A-28HXBPeerless®28HXB — Impeller 2617403
A-SC10C-SP9LSimflo®SC10C-SP9L
A-SE10C-SP9MSimflo®SE10C-SP9M
A-19FKMFloway®19FKM

On phones and smaller screens, swipe the table horizontally to view all columns.

How to Select From an Existing Model

1. Identify the Existing Pump

Send the manufacturer, complete model, bowl designation, serial number and clear nameplate photographs.

2. Confirm the Hydraulic Duty

Provide actual required GPM and TDH rather than assuming the existing pump was correctly selected for current system conditions.

3. Confirm Bowl & Stages

Record bowl size or designation, stage count, impeller information and any existing performance curve.

4. Confirm Construction

Provide bowl, impeller and shaft materials, column size and length, lubrication arrangement and discharge-head details.

5. Confirm the Driver

Provide horsepower, RPM, voltage, phase, frequency, enclosure and available thrust information.

6. Engineer the Replacement

ACCA reviews the identification data and duty together so the proposed replacement is selected for the installation rather than by model name alone.

Manufacturer names and trademarks are the property of their respective owners and are used solely for equipment identification and compatibility reference. ACCA Pumps is an independent supplier and is not affiliated with or endorsed by the referenced manufacturers.