Wastewater Treatment • Chemical Feed

Progressive Cavity Polymer Feed Pumps

Controlled, low-pulsation delivery of viscous and shear-sensitive polymers for sludge conditioning, thickening and dewatering processes.

Wastewater treatment polymer feed and sludge conditioning application
Polymer feed rate should be coordinated with sludge flow, solids loading and dewatering-equipment demand.
Metering & Conditioning

Why progressive cavity pumps are used for polymer feed

Many wastewater polymers are viscous and sensitive to mechanical shear. Progressive cavity pumps combine useful metering behavior with low-pulsation positive-displacement flow and can handle many neat and diluted polymer solutions when correctly selected.

Low pulsation

Smooth delivery supports consistent chemical feed and process control.

Metering behavior

Capacity is approximately proportional to pump speed across the usable range.

Viscous fluids

Suitable for many neat and diluted polymer solutions with proper inlet design.

Low shear

Helps limit unnecessary mechanical degradation of shear-sensitive polymer.

Pump Selection

Size around dosage range, viscosity and displacement

Define minimum, normal and maximum dosage rather than selecting only for peak flow. For very low feed rates, displacement per revolution becomes particularly important, while neat polymer viscosity can strongly influence suction performance.

DosageMinimum, normal & maximum
ViscosityAt actual concentration & temperature
PressureInjection + piping differential
SuctionTank level & inlet losses
TurndownRequired VFD operating range
MaterialsElastomer, seals & wetted metals
Shear Control

The complete polymer feed system matters

Pump speed, rotor/stator geometry, downstream valves, mixers and piping can all contribute to mechanical shear. The pump should deliver the required dosage without unnecessary rotational speed, and the complete conditioning system should be reviewed rather than considering the pump alone.

Coordinate with sludge feed

Effective conditioning promotes floc formation and solids-liquid separation. Polymer dosage should track sludge flow and solids loading for the downstream dewatering equipment.

Materials & Protection

Compatibility should be checked against the actual polymer

Stator elastomer, seals and metallic wetted parts should be checked against the specific polymer formulation, carrier fluid, cleaning chemicals and operating temperature rather than assuming all wastewater polymers behave identically.

Protect the metering pump

  • Discharge-pressure protection
  • Dry-run protection
  • Motor overload protection
  • VFD operating limits
ACCA PUMPS • APPLICATION ENGINEERING

Need a polymer feed pump?

Send the polymer product and concentration, viscosity if known, dosage range, discharge pressure, suction conditions, temperature, material requirements and existing pump information.

Request Engineering Assistance