ACCA AL-SERIES · 3-STAGE L8

ACCA 3L8 Progressive Cavity Pump

Complete 3-stage L8 pump for supported Moyno® 3L8 replacement applications.

The L8 pumping element has 10.7 GPM per 100 RPM theoretical displacement. The 3-stage configuration is selected where greater differential-pressure capability is required than lower-stage L8 configurations.

ACCA 3L8 progressive cavity pump compatible with Moyno 3L8

3L8 Pump Specifications

Stages 3 Theoretical displacement 10.7 GPM / 100 RPM
Suction 4.00 in Discharge 4.00 in
Overall length (CP) 71.12 in Weight 372 lb

How to Read 3L8

3Three pumping stages

Stage count is selected around differential-pressure requirements.

LL-Frame

Identifies the L-Frame drive-end and pumping-element relationship.

8Size-8 pumping element

L8 displacement is 10.7 GPM per 100 RPM.

Important: stage count affects pressure capability; it does not multiply displacement per revolution. 1L8, 2L8 and 3L8 use the same L8 theoretical displacement.

3L8 Theoretical Capacity by Speed

100 RPM10.7 GPM
200 RPM21.4 GPM
400 RPM42.8 GPM
600 RPM64.2 GPM
800 RPM85.6 GPM

Actual delivered flow can be lower depending on differential pressure, viscosity, rotor/stator fit, wear and internal slip.

Materials of Construction & Type Designation

L-Frame pumps use a three-letter Type Designation to identify materials by component group. CDQ is a common standard construction, but it is only one of many available material combinations.

1stSuction / body casting

C Cast Iron · E Alloy CB-20 Stainless · H Hastelloy C · M Monel · S 316 Stainless Steel · W Cast Steel · X Special

2ndWetted metallic internals

D Alloy Steel · E Alloy CB-20 Stainless · G 416 Stainless · H Hastelloy C · J 17-4 PH Stainless · M Monel · S 316 Stainless · X Special

3rdStator material

The third character identifies the stator material only; it does not identify the stator tube/casing material.

Stator Material Codes

Code Material Designation Code Material Designation
B EPDM 300, 70 durometer C Buna-N 103, 50 durometer
D Tool Steel E Buna-N 110, 70 durometer
F Viton 500, 75 durometer G 416 Stainless Steel
H Hastelloy C J 17-4 PH Stainless Steel
K Hypalon 800, 70 durometer M Buna-N 100M, 70 durometer
P Thiokol, 70 durometer Q Buna-N 100, 70 durometer
R Natural Rubber 200, 55 durometer T Teflon, 15% glass
U Urethane, 70 durometer X Special to application
Z Buna-N 150, 70 durometer

Example – CDQ: C = cast-iron suction housing; D = alloy-steel wetted internals; Q = Buna-N / nitrile stator. The three-letter type code should be read as a material system, not as a single fixed construction.

Stator casing: the type designation does not identify the stator tube. ACCA stator references distinguish regular-steel casing (C4 series) and stainless-steel casing (C5 series) where applicable.

Special Construction / Trim Code: Semi-standard and special-construction pumps may include a separate three-character trim code. The first character identifies sealing variations, the second identifies internal variations, and the third identifies rotor variations. When replacing a special-construction pump, provide ACCA with the complete frame, type designation and trim code.

Typical 3L8 Applications

Use these application guides for process-specific selection considerations. Final pump construction should be confirmed against the actual fluid and duty.

Wastewater & Sludge

Sludge transfer and solids-bearing wastewater services.

Explore sludge pump applications →

Marine Fuel & Viscous Transfer

Viscous transfer duties where positive-displacement pumping is appropriate.

Explore marine transfer pumps →

Mining

Abrasive and solids-bearing process duties with construction selected for service.

Explore mining pumps →

3L8 Technical Downloads

3L8 Dimensions & Installation Drawing

Complete dimensional reference including connections, keyway, disassembly clearance and pump weight.

Download Dimensions PDF

L8 Operation & Maintenance Manual

Installation, maintenance, disassembly, inspection, replacement-parts references and service information.

Download O&M Manual

Maintaining an Existing L8 Pump?

Rotors · Stators · Connecting Rod Kits · Drive Components · Bearings · Seals

ACCA supports the installed L8 family with replacement pumping elements and drive-end components.

Browse L8 Replacement Parts

L8 Element Engineering

The L8 pumping element displaces 10.7 GPM per 100 RPM. Pump speed establishes theoretical capacity before slip and application corrections are considered. For abrasive water-based slurries, horsepower allowance must account for solids concentration and particle size. For Newtonian viscous fluids, apply the L8 viscosity horsepower adder appropriate to viscosity, speed and the approved stage configuration. Temperature and rotor fit can also increase required starting torque and horsepower.

Approved ACCA L8 configurations: 1L8, 2L8 and 3L8.

Use the L-Frame Horsepower, Slurry & Viscosity Selection Guide →

Related L8 Pump Configurations

Need a 3L8 Replacement Pump?

Send ACCA the existing pump model and operating conditions. We can review flow, differential pressure, fluid, materials, elastomer and drive requirements.

Moyno® is a registered trademark of its respective owner. ACCA Pumps is independent; model references identify compatible replacement applications.