ACCA AL-SERIES · 1-STAGE L2

ACCA 1L2 Progressive Cavity Pump

Complete 1-stage L2 pump for supported Moyno® 1L2 replacement applications.

The L2 pumping element has 0.24 GPM per 100 RPM theoretical displacement. The 1-stage configuration is selected for lower differential-pressure duties within the L2 family.

ACCA 1L2 progressive cavity pump compatible with Moyno 1L2

1L2 Pump Specifications

Stages 1 Theoretical displacement 0.24 GPM / 100 RPM
Suction 1.00 in Discharge 0.75 in
Overall length (CP) 17.25 in Weight 22 lb

How to Read 1L2

1One pumping stage

Stage count is selected around differential-pressure requirements.

LL-Frame

Identifies the L-Frame drive-end and pumping-element relationship.

2Size-2 pumping element

L2 displacement is 0.24 GPM per 100 RPM.

Important: stage count affects pressure capability; it does not multiply displacement per revolution. 1L2, 2L2 and 3L2 use the same L2 theoretical displacement.

1L2 Theoretical Capacity by Speed

100 RPM0.24 GPM
200 RPM0.48 GPM
400 RPM0.96 GPM
600 RPM1.44 GPM
800 RPM1.92 GPM

Actual delivered flow can be lower depending on differential pressure, viscosity, rotor/stator fit, wear and internal slip.

Materials of Construction & Type Designation

L-Frame pumps use a three-letter Type Designation to identify materials by component group. CDQ is a common standard construction, but it is only one of many available material combinations.

1stSuction / body casting

C Cast Iron · E Alloy CB-20 Stainless · H Hastelloy C · M Monel · S 316 Stainless Steel · W Cast Steel · X Special

2ndWetted metallic internals

D Alloy Steel · E Alloy CB-20 Stainless · G 416 Stainless · H Hastelloy C · J 17-4 PH Stainless · M Monel · S 316 Stainless · X Special

3rdStator material

The third character identifies the stator material only; it does not identify the stator tube/casing material.

Stator Material Codes

Code Material Designation Code Material Designation
B EPDM 300, 70 durometer C Buna-N 103, 50 durometer
D Tool Steel E Buna-N 110, 70 durometer
F Viton 500, 75 durometer G 416 Stainless Steel
H Hastelloy C J 17-4 PH Stainless Steel
K Hypalon 800, 70 durometer M Buna-N 100M, 70 durometer
P Thiokol, 70 durometer Q Buna-N 100, 70 durometer
R Natural Rubber 200, 55 durometer T Teflon, 15% glass
U Urethane, 70 durometer X Special to application
Z Buna-N 150, 70 durometer

Example – CDQ: C = cast-iron suction housing; D = alloy-steel wetted internals; Q = Buna-N / nitrile stator. The three-letter type code should be read as a material system, not as a single fixed construction.

Stator casing: the type designation does not identify the stator tube. ACCA stator references distinguish regular-steel casing (C4 series) and stainless-steel casing (C5 series) where applicable.

Special Construction / Trim Code: Semi-standard and special-construction pumps may include a separate three-character trim code. The first character identifies sealing variations, the second identifies internal variations, and the third identifies rotor variations. When replacing a special-construction pump, provide ACCA with the complete frame, type designation and trim code.

Typical 1L2 Applications

Use these application guides for process-specific selection considerations. Final pump construction should be confirmed against the actual fluid and duty.

Wastewater & Sludge

Sludge transfer and solids-bearing wastewater services.

Explore sludge pump applications →

Polymer Feed

Controlled low-shear handling for wastewater polymer-feed duties.

Explore polymer feed pumps →

Chemical Processing

Process-fluid transfer with materials selected for the chemical service.

Explore chemical-processing pumps →

1L2 Technical Downloads

1L2 Dimensions & Installation Drawing

Complete dimensional reference including connections, keyway, disassembly clearance and pump weight.

Download Dimensions PDF

L2 Operation & Maintenance Manual

Installation, maintenance, disassembly, inspection, replacement-parts references and service information.

Download O&M Manual

Maintaining an Existing L2 Pump?

Rotors · Stators · Connecting Rod Kits · Drive Components · Bearings · Seals

ACCA supports the installed L2 family with replacement pumping elements and drive-end components.

Browse L2 Replacement Parts

L2 Element Engineering

The L2 pumping element displaces 0.24 GPM per 100 RPM. Pump speed establishes theoretical capacity before slip and application corrections are considered. For abrasive water-based slurries, horsepower allowance must account for solids concentration and particle size. For Newtonian viscous fluids, apply the L2 viscosity horsepower adder appropriate to viscosity, speed and stage count. Temperature and rotor fit can also increase required starting torque and horsepower.

Approved ACCA L2 configurations on this site: 1L2, 2L2 and 3L2.

Use the L-Frame Horsepower, Slurry & Viscosity Selection Guide →

Related L2 Pump Configurations

Need a 1L2 Replacement Pump?

Send ACCA the existing pump model and operating conditions. We can review flow, differential pressure, fluid, materials, elastomer and drive requirements.

Moyno® is a registered trademark of its respective owner. ACCA Pumps is independent; model references identify compatible replacement applications.